Warning Array Has Disk With Read Errors

Issues happened again ....

I run smart tests, and even if the quickest one succeed without issues, the longest fails at ten% with the post-obit bulletin: "Errors occurred - Check SMART written report"

And then here is the results:

ATA Error Count: 24 (device log contains merely the most recent v errors)   CR = Command Register [HEX]   FR = Features Register [HEX]   SC = Sector Count Annals [HEX]   SN = Sector Number Register [HEX]   CL = Cylinder Low Register [HEX]   CH = Cylinder High Register [HEX]   DH = Device/Head Register [HEX]   DC = Device Control Annals [HEX]   ER = Mistake register [HEX]   ST = Status register [HEX] Powered_Up_Time is measured from ability on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" subsequently 49.710 days.  Error 24 occurred at disk ability-on lifetime: 615 hours (25 days + 15 hours)   When the command that acquired the error occurred, the device was active or idle.    After control completion occurred, registers were:   ER ST SC SN CL CH DH   -- -- -- -- -- -- --   twoscore 51 00 88 a1 95 e0  Fault: UNC at LBA = 0x0095a188 = 9806216    Commands leading to the command that acquired the mistake were:   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name   -- -- -- -- -- -- -- --  ----------------  --------------------   c8 00 00 78 a0 95 e0 08      17:fifteen:44.108  READ DMA   c8 00 00 78 9f 95 e0 08      17:fifteen:44.107  READ DMA   c8 00 00 78 9e 95 e0 08      17:15:44.107  READ DMA   c8 00 00 78 9d 95 e0 08      17:15:44.104  READ DMA   c8 00 00 78 9c 95 e0 08      17:15:44.103  READ DMA  Fault 23 occurred at disk power-on lifetime: 615 hours (25 days + 15 hours)   When the command that caused the error occurred, the device was active or idle.    Afterwards command completion occurred, registers were:   ER ST SC SN CL CH DH   -- -- -- -- -- -- --   xl 51 00 a8 fb 94 e0  Error: UNC at LBA = 0x0094fba8 = 9763752    Commands leading to the command that caused the fault were:   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name   -- -- -- -- -- -- -- --  ----------------  --------------------   c8 00 00 78 ec 94 e0 08      17:xv:30.205  READ DMA   c8 00 00 78 eb 94 e0 08      17:xv:30.205  READ DMA   c8 00 00 78 ea 94 e0 08      17:15:30.205  READ DMA   c8 00 00 78 e9 94 e0 08      17:15:xxx.202  READ DMA   c8 00 00 78 e8 94 e0 08      17:15:xxx.202  READ DMA  Error 22 occurred at deejay power-on lifetime: 615 hours (25 days + fifteen hours)   When the command that caused the error occurred, the device was active or idle.    After command completion occurred, registers were:   ER ST SC SN CL CH DH   -- -- -- -- -- -- --   40 51 00 78 cc 93 e0  Error: UNC at LBA = 0x0093cc78 = 9686136    Commands leading to the control that acquired the error were:   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name   -- -- -- -- -- -- -- --  ----------------  --------------------   c8 00 00 78 b0 93 e0 08      17:15:07.011  READ DMA   c8 00 00 78 af 93 e0 08      17:xv:07.011  READ DMA   c8 00 00 78 ae 93 e0 08      17:15:07.010  READ DMA   c8 00 00 78 ad 93 e0 08      17:15:07.008  READ DMA   c8 00 00 78 air-conditioning 93 e0 08      17:15:07.008  READ DMA  Error 21 occurred at disk power-on lifetime: 615 hours (25 days + 15 hours)   When the command that caused the fault occurred, the device was active or idle.    After command completion occurred, registers were:   ER ST SC SN CL CH DH   -- -- -- -- -- -- --   40 51 00 d8 4f 93 e0  Error: UNC at LBA = 0x00934fd8 = 9654232    Commands leading to the command that acquired the mistake were:   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name   -- -- -- -- -- -- -- --  ----------------  --------------------   c8 00 00 78 a9 92 e0 08      17:14:54.023  READ DMA   c8 00 00 78 a8 92 e0 08      17:14:54.023  READ DMA   c8 00 00 78 a7 92 e0 08      17:xiv:54.022  READ DMA   c8 00 00 78 a6 92 e0 08      17:xiv:54.022  READ DMA   c8 00 00 78 a5 92 e0 08      17:14:54.020  READ DMA  Error 20 occurred at disk power-on lifetime: 615 hours (25 days + 15 hours)   When the control that caused the fault occurred, the device was active or idle.    Later command completion occurred, registers were:   ER ST SC SN CL CH DH   -- -- -- -- -- -- --   forty 51 00 a0 20 92 e0  Mistake: UNC at LBA = 0x009220a0 = 9576608    Commands leading to the control that caused the error were:   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name   -- -- -- -- -- -- -- --  ----------------  --------------------   c8 00 00 78 xx 92 e0 08      17:xiv:41.626  READ DMA   c8 00 00 78 1f 92 e0 08      17:14:41.625  READ DMA   c8 00 00 78 1e 92 e0 08      17:14:41.625  READ DMA   c8 00 00 78 1d 92 e0 08      17:14:41.623  READ DMA   c8 00 00 78 1c 92 e0 08      17:14:41.623  READ DMA        

And hither is the disk informations:

Screenshot%202016-09-23%2013.31.57.png?dl=1

Thanks for your aid

mascarenasahme1941.blogspot.com

Source: https://forums.unraid.net/topic/49870-array-has-1-disk-with-read-errors-what-should-i-do/

Belum ada Komentar untuk "Warning Array Has Disk With Read Errors"

Posting Komentar

Iklan Atas Artikel

Iklan Tengah Artikel 1

Iklan Tengah Artikel 2

Iklan Bawah Artikel