Warning Array Has Disk With Read Errors
Issues happened again ....
I run smart tests, and even if the quickest one succeed without issues, the longest fails at ten% with the post-obit bulletin: "Errors occurred - Check SMART written report"
And then here is the results:
ATA Error Count: 24 (device log contains merely the most recent v errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Annals [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Control Annals [HEX] ER = Mistake register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from ability on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" subsequently 49.710 days. Error 24 occurred at disk ability-on lifetime: 615 hours (25 days + 15 hours) When the command that acquired the error occurred, the device was active or idle. After control completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- twoscore 51 00 88 a1 95 e0 Fault: UNC at LBA = 0x0095a188 = 9806216 Commands leading to the command that acquired the mistake were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 78 a0 95 e0 08 17:fifteen:44.108 READ DMA c8 00 00 78 9f 95 e0 08 17:fifteen:44.107 READ DMA c8 00 00 78 9e 95 e0 08 17:15:44.107 READ DMA c8 00 00 78 9d 95 e0 08 17:15:44.104 READ DMA c8 00 00 78 9c 95 e0 08 17:15:44.103 READ DMA Fault 23 occurred at disk power-on lifetime: 615 hours (25 days + 15 hours) When the command that caused the error occurred, the device was active or idle. Afterwards command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- xl 51 00 a8 fb 94 e0 Error: UNC at LBA = 0x0094fba8 = 9763752 Commands leading to the command that caused the fault were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 78 ec 94 e0 08 17:xv:30.205 READ DMA c8 00 00 78 eb 94 e0 08 17:xv:30.205 READ DMA c8 00 00 78 ea 94 e0 08 17:15:30.205 READ DMA c8 00 00 78 e9 94 e0 08 17:15:xxx.202 READ DMA c8 00 00 78 e8 94 e0 08 17:15:xxx.202 READ DMA Error 22 occurred at deejay power-on lifetime: 615 hours (25 days + fifteen hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 78 cc 93 e0 Error: UNC at LBA = 0x0093cc78 = 9686136 Commands leading to the control that acquired the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 78 b0 93 e0 08 17:15:07.011 READ DMA c8 00 00 78 af 93 e0 08 17:xv:07.011 READ DMA c8 00 00 78 ae 93 e0 08 17:15:07.010 READ DMA c8 00 00 78 ad 93 e0 08 17:15:07.008 READ DMA c8 00 00 78 air-conditioning 93 e0 08 17:15:07.008 READ DMA Error 21 occurred at disk power-on lifetime: 615 hours (25 days + 15 hours) When the command that caused the fault occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 d8 4f 93 e0 Error: UNC at LBA = 0x00934fd8 = 9654232 Commands leading to the command that acquired the mistake were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 78 a9 92 e0 08 17:14:54.023 READ DMA c8 00 00 78 a8 92 e0 08 17:14:54.023 READ DMA c8 00 00 78 a7 92 e0 08 17:xiv:54.022 READ DMA c8 00 00 78 a6 92 e0 08 17:xiv:54.022 READ DMA c8 00 00 78 a5 92 e0 08 17:14:54.020 READ DMA Error 20 occurred at disk power-on lifetime: 615 hours (25 days + 15 hours) When the control that caused the fault occurred, the device was active or idle. Later command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- forty 51 00 a0 20 92 e0 Mistake: UNC at LBA = 0x009220a0 = 9576608 Commands leading to the control that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 78 xx 92 e0 08 17:xiv:41.626 READ DMA c8 00 00 78 1f 92 e0 08 17:14:41.625 READ DMA c8 00 00 78 1e 92 e0 08 17:14:41.625 READ DMA c8 00 00 78 1d 92 e0 08 17:14:41.623 READ DMA c8 00 00 78 1c 92 e0 08 17:14:41.623 READ DMA
And hither is the disk informations:
Thanks for your aid
mascarenasahme1941.blogspot.com
Source: https://forums.unraid.net/topic/49870-array-has-1-disk-with-read-errors-what-should-i-do/
Belum ada Komentar untuk "Warning Array Has Disk With Read Errors"
Posting Komentar